Atrial fibrillation continues to face limitations in long-term treatment success due to PV reconnection, anatomical variability, and procedural inefficiencies, which restrict the ability to deliver treatment to more patients. This thesis explored key elements along the AF ablation workflow, including pre procedural imaging, lesion delivery parameters, anatomical predictors of recurrence, and procedural efficiency, aiming to streamline strategies that improve safety, efficacy and procedural capacity.
We first evaluated a novel non-contrast enhanced CMR sequence as an alternative to TEE and contrast-enhanced CT for pre‑procedural LAA thrombus exclusion and anatomical planning. BOOST CMR reliably ruled out LAA thrombus, provided accurate LA and PV anatomical assessment, and was substantially better tolerated by patients. Beyond pre-procedural imaging, we also investigated the prognostic value of patient-specific anatomical factors. In a cohort examined with pre-procedural contrast-enhanced CT, an abutting LAA-LSPV – defined as an endocardial distance <2 mm between the two structures – was present in more than half of the patients and emerged as the strongest independent predictor of post-ablation AF recurrence. This observation identifies a high-risk anatomical subgroup that may benefit from localized intensified lesion delivery. We then focused on determinants of effective lesion delivery during RF ablation. We analyzed procedural characteristics of vHPSD RFCA and found that peak temperature significantly correlated with CF. A CF ≥5 g was associated with higher tissue heating, whereas occasional higher CF values (i.e., >25 g) were not linked to complications. These findings highlight the central role of adequate CF in ensuring lesion quality and procedural safety during vHPSD ablation. Finally, we compared PFA and vHPSD ablation. PFA shortened room time by 17 minutes and reduced the duration of most procedural subsections, regardless of operator experience, with no difference in safety or 6 month efficacy. Such reduction translates into the capacity to perform an extra procedure after every 4 cases.
Together, these studies demonstrate how advanced imaging, anatomical risk stratification, optimized lesion delivery parameters, and improved procedural efficiency can improve AF ablation workflows. Integrating these elements into clinical practice may help increase procedural capacity, reduce recurrences, and improve outcomes.